Advanced Search
Telect 200A Fuse Panel 009-8004-0208
We apologize but this item is currently unavailable. Please feel free to browse our website for other available items.
Enlarge
Item Code:
TELE00980040208
Manufacturer:
Model:
009-8004-0208
Category:
Item Condition Description:
Please note, this unit is used and has minor scuffs and scratches, but is fully operational & functions as intended. Comes with rack ears only! No Telect Fuse Alarm 4000315, cables or any other accessories!
Item Description

Telect Dual-Feed 200A 8/8 KLM/GMT Fuse Panel 009-8004-0208. Gain high input amperage, high-density fuse outputs and intermediate- and low-current distribution capabilities in one compact unit with the 8/8 KLM/GMT fuse panel.
 
Telect Part Number: 009-8004-0208







Features:

• High power density: 125 amp input interrupt device rating per side (dual feed) in two rack units
• Large range of output amperages:
— 1-30A per KLM fuse output
— 8/100-15A per GMT fuse output
• Versatile wire binding output connections: Accept either bare or compression-lug cable
• Robust input connections: Accept secure two-hole compression lug cable
• Multiple voltages: Automatically accepts ±24V, -48V
• Sophisticated alarming: Intelligent, removable alarm card features a KLM alarm reset feature and requires no extra alarming fuses







Specifications:

Mechanical
• 17.25" W x 3.5" H (2RU) x 9" D (43.82 cm x 8.81 cm x 22.86 cm)
• 13.5 lbs. (6.12 kg), 15 lbs. (6.80 kg) shipping weight
• 19" or 23" with EIA and WECO hole spacing brackets provided
• Panel comes with brackets in the 19" configuration
Connections
• Input lugs: 2-hole compression lug, 5/16" stud size on 1" center hole spacing; wire size up to 4/0 AWG
• Output lugs: .25" wire clamping screw; wire size #10 to #22 AWG
• Ground lugs: 2-hole compression lug, .25" stud size on .625" center hole spacing; wire size up to #1 AWG
Electrical
• Max. continuous input load rating: 200 amps per load per side
• Max. input interruption device rating: 250 amps
• Max. continuous output load rating: 25 amps per KLM fuse; 12 amps per GMT fuse; 200 total amps per side
• Alarm displays:
– Green LED—power to sides A and B
– Red LED—fuse failure
– Form C alarm relay contact for power alarms and fuse failure alarms
– Form C contacts rated at 2 amps for 30 VDC; 0.6 amps for
–48 VDC and 60 VDC; 1 amp for 120 VAC
• Fuse alarm reset: Resets existing KLM fuse alarm condition
• Operating temperature range: -10° C to +55° C
• Power dissipation at full load: 65 W per side
• Power dissipation with no load: 5.6 W per side
• Operating voltages: -20 to –60 VDC; +20 to +30 VDC
• Interrupt devices: KLM type fuses with 30 amps max. rating; GMT fuses with 15 amps max. rating